Sayma Enterprise | Best Fire Sprinkler system provider in Bangladesh.WE ARE WORKING WITH SAME WORLD RECOGNIZED BRAND. IT HAS CAPABILITY TO SERVE QUALITY WORK AND PRODUCTS TO CLIENTS. OUR ENGINEERS, MARKETING PEOPLE & TECHNICIAN ARE WELL SKILLED TO SATISFY OUR VALUED CUSTOMERS. ALSO WE PROVIDE ALL IT AND SECURITY SOLUTION RELATED CONSULTANCY SERVICES IF NEEDED AT FREE OF COST SO WE WANT TO MAKE STEPS AHEAD WITH YOU.
Sayma Enterprise | Best Fire Sprinkler system provider in Bangladesh.Fire Protection Systems Solutions, Fire Protection System | Fire Fighting Products Bangladesh, Best fire Safety Company in Bangladseh || fire protection, Best Fire Protection Companies in Bangladesh. Best Fire Protection Service Provider Company in bd, Fire Protection System | Fire Fighting Products Bangladesh, Fire sprinkler system company bd, Fire Protection Solutions in Bangladesh, Fire door and Fire equipment supplier in Bangladesh, Fire Hydrant & Fire Sprinkler system installation services, Fire Sprinkler & Hydrant System Supplier Company, Best Fire safety company in Bangladesh, Fire Extinguisher Price in Bangladesh Fire Hydrant System installer company in bd, Fire Protection System Provider bd .

Importance of Fire Sprinklers

• Automatic sprinklers are widely recognized as the number one tool of fire protection • In over one hundred years of use, there has never been a multiple fatality of building occupants from fire in a building with a properly designed, installed, and maintained sprinkler system • Sprinklers respond to a fire while it is still small, preventing the fire from developing into a major threat

How reliable are sprinklers?

How reliable are sprinklers? • Records of fires in buildings with supervised automatic fire sprinkler systems have indicated successful extinguishment or control in more than 99% of fire incidents. No other fire protection system or feature has a comparable record of reliability. • Most fires are contained by one or two sprinklers.

What about water damage?

• Because sprinklers attack the fire while it is still small, the total amount of water needed for fire suppression is small (often less than 50 gallons per minute) • Without sprinkler protection, a fire is permitted to grow and the fire department will typically apply hundreds of gallons of water per minute during their operations • For this reason, total amounts of water used in sprinklered buildings approximate one-tenth the amounts used for fires in nonsprinklered buildings
• The likelihood of a sprinkler discharging water in the absence of a fire is very small • Each model of sprinkler is subjected to rigorous laboratory tests to guarantee long-term integrity, and every single sprinkler is hydrostatically tested at twice the maximum system water pressure prior to leaving the factory • Sprinkler guards should be used in environments where sprinklers could be damaged Aren’t Sprinkler Systems Expensive? • No, in fact sprinklers can often reduce the total cost of construction • Typically, sprinkler systems can be installed for about 1% of building cost, or less than $2 per square foot • If the decision to install sprinklers is made early enough in the planning process, sprinklers can actually reduce total construction costs through the use of code incentives or “trade-ups” Aren’t Sprinkler System

Expensive?

• In recognition of the superior fire protection afforded by sprinklers, codes permit reductions in fire resistance ratings, longer exit travel distances, and a wider range of interior finish materials in sprinklered buildings • Insurance rates are substantially less for sprinklered facilities • These incentives make it possible to build a safer building for less money The best fire protection system is… …the one that works when it’s needed.

Sprinkler System Components

• Basic components: – Sprinklers – System piping – A dependable water source – Most systems also require an alarm and system control valves Sprinkler Head Components • The typical sprinkler consists of a frame, thermal operated linkage, cap, orifice, and deflector • Styles of each component may vary but the basic principles of each remain the same Sprinkler Head Components • Frame – The frame provides the main structural component which holds the sprinkler together. – The water supply pipe connects to the sprinkler at the base of the frame – The frame holds the thermal linkage and cap in place, and supports the deflector during discharge Sprinkler Head Components • Thermal linkage – The thermal linkage is the component which controls water release – Under normal conditions the linkage holds the cap in place and prevents water flow – Common linkage styles include soldered metal levers, frangible glass bulbs, and solder pellets Sprinkler Head Components • Cap – The cap provides the water tight seal which is located over the sprinkler orifice. – This component is held in place by the thermal linkage – Operation of the linkage causes the cap to fall from position and permit water flow Sprinkler Head Components • Orifice – A machined opening at the base of the sprinkler frame – It is from this opening which extinguishing water flows • Deflector – The deflector is mounted on the frame opposite the orifice – The purpose of this component is to break up the water stream discharging from the orifice into a more efficient extinguishing pattern – Deflector styles determine how the sprinkler is mounted